Tweet |
Custom Search
|
|
|
||
TM 9-2330-330-14&P
FUEL SYSTEM TROUBLESHOOTING
0014 00
Table 1. Troubleshooting Procedures--Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3.
FUEL DOES NOT FLOW
1.
Check to see if emergency
If valve A is in closed position,
DURING ANY NON-
valve A control handle is in
open it. Verify problem is solved.
FILTERED FUELING
the open position.
If valve is already in open
OPERATION
position, go to step 2.
2.
Verify all valves are set per
Set valves per schematic on tool
fuel operations schematic.
box lid (refer to WP 0007 00).
Verify problem is solved. If valves
are already set properly, go to
step 3.
3.
Check for debris or dirt in
If dirt or debris are present in
nozzle screen of quick
nozzle screen, clean screen per
coupling.
solved. If dirt and debris are not
present, go to step 4.
4.
Check pump inlet screen for Clean inlet screen per WP 0041
debris or dirt clogging inlet.
screen was clean, notify
Organizational maintenance that
further troubleshooting is
required.
END OF TASK
0014 00-3/4 blank
|
||