e. Remove 4-in. hose (4) from hose tube (5) and connect to bottom loading connection
(3) and fuel facility.
f.
Place valve D (2) in open position.
g. Commence bottom loading.
h. After flow has begun, set valve D (2) to closed position to precheck automatic shut off.
If shut off is functional, flow should stop after 2025 seconds.
i.
Set valve D (2) to open position. Flow will resume in about 20 seconds.
WARNING
If fuel flow into semitrailer stops because of a shut off
malfunction, or the presence of leaks, or if any other
unusual conditions are observed, stop fuel supply at
loading facility and notify your supervisor.
OPERATION UNDER USUAL CONDITIONS--Continued
j.
When tank is full, fuel flow will stop automatically. When fueling is complete return all valves to
the closed position.
k.
Close valve D (2). Disconnect hose (4) from bottom loading connection (3) and install cover.
Drain hose into suitable container and store hose (4) in hose tube (5).
l.
Open valves A, D, H, and J (8, 2, 6, and 7) and drain accumulated water into a suitable
container.
m. Close all valves and vapor recovery system vent cap.
n. Remove all grounding and bonding cables.
o. Store and cover fire extinguishers (1).