Custom Search
 
  
 


TM 9-2330-329-14&P
4-INCH PUMP MAINTENANCE--Continued
0146 00
NOTE
Install same thickness of gasket(s) as previously removed.
12.
Install new gasket(s) (13), intermediate housing (1), eight new lockwashers (12), and nuts (11) to
pump (6) as an assembly.
NOTE
A clearance of 0.010 to 0.020 in. (0.25 to 0.51 mm) between
impeller and wear plate. Set this clearance by adding or removing
gasket(s).
13.
Check for clearance between front of impeller (21) and wear plate (20). If impeller scrapes, add
another gasket (13) of sufficient thickness between seal plate (25) and volute (18).
0146 00-8



 