Plug and receptacle assemblies:
1) Strip cable insulation equal to depth of solder wells of inserts.
2) Pass cable ends through grommet retaining nut, grommet, and coupling nut and into
solder wells of inserts and solder.
3) Slide grommet over inserts and press into shell assembly until seated.
4) Thread grommet retaining nut to shell assembly until seated.