Conduits are stocked in bulk lengths. Measure original
conduit and cut new conduit to same length. Trim ends
of conduit to get a smooth, square cut.
1.
Install conduit nut (2), new insert (4), and new sleeve (5) onto end of new conduit (6).
2.
Install new conduit (6), new insert (4), and new sleeve (5) into end of fitting (1).
3.
Tighten nut (3) at fitting (1).
4.
Install conduit nut (2) onto fitting (1) and tighten.
5.
Install new conduit (6) to clips (7) and bend to secure.
FOLLOW-ON TASKS
1.
Install front marker light cable (WP 0056 00).
2.
Reconnect negative battery terminal (WP 0007 00).
3.
Disconnect semitrailer grounding cables (WP 0007 00).
END OF TASK