Tweet |
Custom Search
|
|
|
||
TM 9-2330-329-14&P
MAIN WIRING HARNESS MAINTENANCE--Continued
0055 00
NOTE
Connectors must be cut from harness leads in order to
fit through conduit.
11.
Pull main wiring harness (33) through conduit (32) from composite stoplight assembly box (26) to
electrical junction box (14).
12.
Pull harness (33) through conduit (34) from electrical junction box (14) to front bulkhead (4).
INSPECTION
Inspect wiring harness for cracked or missing insulation, frayed or exposed wires, and loose or damaged
connectors. If any of these conditions exist, repair per WP 0062 00.
INSTALLATION
1.
Install leads of harness (33) to front of bulkhead (4) through conduit (34) to electrical junction
box (14).
2.
From electrical junction box (14), install leads of harness (33) through conduit (32) to the roadside
composite stoplight assembly (26).
0055 00-4
|
||