b.
Installation.
1.
Connect diagnostic/power cable (7) to ECU valve, power supply, and mounting bracket (3), installing
four screws (4), eight washers (5) and four new locknuts (6).
2.
Connect diagnostic tool (1) to diagnostic/power cable (7).
3.
Connect four sensor cables (8) to ECU valve.
4.
Connect four sensor cables (8) to four sensors (9).
5.
Install four sensors (9) to inside hubs of the four inner wheels.
6.
Secure sensors (9) to wheel hubs with sensor clips (10).
CAUTION
Sensor cables must be nylon strapped at the 12 o'clock or 3 o'clock position
on the axle (top or rearward side of axle) to protect them during off-road
operation. Use as many nylon straps as required to insure the cables are
tightly secured to the axle ends.
NOTE
Attach nylon tiedown straps (11) to axle allowing for easy replacement--
locking tab shall be situated within 90 of axle top.
7.
Secure sensor cables (8) to axle with nylon tiedown straps (11).