Custom Search
 
  
 


TM 9-2320-279-10-3
Preventive Maintenance Checks and Services (PMCS) (Cont)
2-97. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) TABLE
(CONT).
Table 2-9. Operator/Crew Preventive Maintenance Checks and Service (PMCS) (Cont)
NOTE: These checks are to be made in the order listed, within designated interval.
A-After Operation
D-During Operation
W-Weekly
M-Monthly
INTERVAL
ITEM TO BE INSPECTED PROCEDURE:
Item
Check for and have repaired, filled, or adjusted
NOT MISSION
No. A D W M
as needed.
CAPABLE IF:
GENERATOR (CONT).
21.
Generator
a. Start hydraulic generator (para 2-112).
inoperable.
b. Check that ammeter and voltmeter indicate
smooth 120 VAC output.
WARNING
Use extreme care when working around
120 VAC receptacles. Personnel may get
electrocuted if 120 VAC receptacles are
exposed to water. Failure to comply may
result in injury or death to personnel.
c. Check operation of 120 VAC accessories
(crew cab air conditioner, flood lights, and
receptacles).
d. Stop hydraulic generator (para 2-112).
110
2-70



 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business