TM 9-2320-279-10-3
Preventive Maintenance Checks and Services (PMCS) (Cont)
Table 2-9. Operator/Crew Preventive Maintenance Checks and Service (PMCS) (Cont)
NOTE: These checks are to be made in the order listed, within designated interval.
A-After Operation
D-During Operation
W-Weekly
M-Monthly
INTERVAL
ITEM TO BE INSPECTED PROCEDURE:
Item
Check for and have repaired, filled, or adjusted
NOT MISSION
No. A D W M
as needed.
CAPABLE IF:
PERSONNEL CAB ASSEMBLY, LIGHTS AND
15.
CONTROLS (CONT).
Window Deluge System
a. Check operation of window deluge system
b. Inspect nozzles, hoses, and fittings for leaks
and obvious damage.
tfft00128p
DELUGE SYSTEM
PUMP COMPARTMENT.
16.
Inspect discharge connections/adapters for visible
distortion, thread damage, and cracks.
Inspect driver side panels, pump operators panel,
enclosure covers, and running boards for visible
damage. Check all attaching hardware for damage
and/or missing parts.
2-59