TM 10-6640-239-13
4-104
4-44. DISTILLATION TEST APPARATUS.
This task consists of:
a.
Remove
b.
Install
INIT IAL SET-UP
Tools Required
General Mechanics Tool Kit, (Appendix B, Section III, Item 1)
Materials/Parts Required
Lockwashers, (8)
Personnel Required
Two (2)
General Safety Instructions
WARNING
ELECTRICAL SHOCK
Before performing any maintenance actions on electrical equipment, ensure all
electrical power has been turned off. Failure to comply with this warning may
result in serious injury or death.
REMOVE
Remove Distillation Test Apparatus. See Figure 4-38.
a.
Unplug distillation test apparatus (1) from wall receptacle.
WARNING
Serious injury to personnel or damage to equipment may occur unless two or more
personnel are used to remove Distillation Test Apparatus because of weight.
b.
Remove four screws (2), washers (3), lockwashers (4), nuts (5), and distillation test apparatus (1) with plate (6) from
curbside countertop. Discard lockwashers.
c.
Carefully remove rear side panels (7).
d.
Remove four screws (8), lockwashers (9), washers (10), clamps (11), and plate (6) from distillation test apparatus
(1). Discard lockwashers.
INSTALL
Install Distillation Test Apparatus. See Figure 4-38.
a.
Install plate (6) to distillation test apparatus (1) and secure with four screws (8), lockwashers (9), washers (10), and
clamps (11). Install rear side panels (7).
WARNING
Serious injury to personnel or damage to equipment may occur unless two or more
personnel are used to install Distillation Test Apparatus because of weight.
b.
Install distillation test apparatus (1) to curbside countertop and secure with four screws (2), washers (3), lockwashers
(4), and nuts (5).