TM 10-6640-239-13
4-102
4-43. KINEMATIC VISCOSITY BATH.
This task consists of:
a.
Remove
b.
Install
INITIAL SET-UP
Tools Required
General Mechanics Tool Kit, (Appendix B, Section III, Item 1)
Materials/Parts Required
Lockwashers, (10)
Personnel Required
Two (2)
General Safety Instructions
WARNING
ELECTRICAL SHOCK
Before performing any maintenance actions on electrical equipment, ensure all
electrical power has been turned off. Failure to comply with this warning may
result in serious injury or death.
REMOVE
Remove Kinematic Viscosity Bath. See Figure 4-37.
a.
Unplug viscosity bath (1) from wall receptacle.
WARNING
Serious injury to personnel or damage to equipment may occur unless two or more
personnel are used to remove Kinematic Viscosity Bath because of weight.
b.
Remove drawers J1 and K1 to gain access to hardware.
c.
Remove ten screws (2) securing two angles (3) to kinematic viscosity bath (1) and remove kinematic viscosity bath.
d.
Remove ten screws (4), washers (5), lockwashers (6), nuts (7), and two angles (3) from roadside countertop.
Discard lockwashers.
INSTALL
Install Kinematic Viscosity Bath. See Figure 4-37.
a.
Install two angles (3) to roadside countertop and secure with ten screws (4), washers (5), lockwashers (6), and
nuts (7).
WARNING
Serious injury to personnel or damage to equipment may occur unless two or more
personnel are used to install Kinematic Viscosity Bath because of weight.
b.
Install kinematic viscosity bath (1) onto roadside countertop and secure with ten screws (2).
c.
Plug kinematic viscosity bath (1) into wall receptacle.
d.
Verify kinematic viscosity bath operation.
|
|