Table 4-1. Unit Preventive Maintenance Checks and Services (PMCS)
Q - Quarterly S - Semi-Annually A - Annually B-Bi-Annually
NOTE
If equipment must be kept in continuous operation, inspect and service those
items that can be inspected and serviced without disturbing operation. Make
complete Inspections and services when equipment can be shut down. Within
designated interval, these checks are to be performed in the order listed.
Perform operator/crew PMCS prior to or in conjunction with unit PMCS if:
There is a delay between the daily operation of the equipment and the unit or
regular operator is not assisting/participating.
Item No.
Interval
Item to Inspect
Procedures
Not Fully Mission Capable If:
Q
S
A
B
1
Mod Lab B
Trailer
Perform PMCS per TM listed in
Appendix A.
Fails inspection per TM.
2
a. Check door panel and gasket
for correct assembly and good
condition. Check water hose
adapters for correct assembly
and good condition.
Water hose adapters incorrectly
assembled or damaged.
Water Supply Box
b. Check directional valve lever
for proper operation.
Directional valve lever inoperable.
3
a. Check door panel and gasket
for correct assembly and good
condition.
Door or hinge damaged or missing.
b. Check electrical connector and
cover for damage.
Electrical connector and cover
damaged.
c. Check grounding lug for
damage and presence of safety
clip.
Grounding lug damaged. Safety
clip missing.
Power Panel
d. Check 110V, 60Hz service
outlet and cover for damage.
110V, 60Hz service outlet and
cover damaged.
e. Check phone connector for
damage.
Phone connector damaged.
4
Gas Cylinder and
Propane Locker
Vents
Check vents and screens for good
condition.
Vents clogged. Bent or broken
screens.
5
Fume Hood Vent
Door
Check door panel and gasket for
correct assembly and good
condition.
Any damage that prevents proper
venting.
|
|