TM 10-6640-238-13
2-40
Table 2-14. Operator Preventive Maintenance Checks and Services (PMCS) - CONT
NOTE
If equipment must be kept in continuous operation, only do procedures that can be
performed without disturbing operation. Make the complete checks and services when
equipment can be shut down.
BE - Before AF After
MO - Monthly
DU- During WE Weekly
Interval
Item No.
B
E
D
U
A
F
W
E
M
O
Item to Inspect
Procedures
Not Fully Mission
Capable If:
37
Vacuum System,
Valves and
Piping
Inspect for leaks, leaky valves,
or inoperative valves.
Leaks or defective valves.
38
a.
Inspect mounting.
Missing mounting screws.
b.
Inspect for leaks.
Class III leaks detected.
Water Filter
c.
Inspect for clogged filter.
Filter is clogged.
39
a. Inspect for damage.
Missing fasteners. Class III
leaks detected.
High Pressure
Steam Boiler
b. Inspect for proper operation.
Inoperative boiler.
40
a. Inspect shock mounts.
Missing screws or shock
mounts.
Centrifuge
b. Inspect for proper operation.
Inoperative centrifuge.
41
Field Testing Kits
Inspect kits contained in cases.
Defective kits and missing
components.
42
a. Inspect for damage.
Missing fasteners.
Freezer
b. Inspect for proper operation.
Freezer is inoperative.
43
Gas Cylinder
Storage Locker
a. Inspect cylinders for leaks.
Gas supply cylinder leaking
b. Inspect for ice maker bag.
Ice bag missing.
44
a. Inspect for damage.
Missing screws.
Refrigerator
b. Inspect for proper operation.
Refrigerator is inoperative.
45
a. Inspect damage.
Separometer is missing items.
Separometer
b. Inspect for proper operation.
Separometer is inoperative.
46
Gas Cylinder and
Propane Lock
Vents
Inspect for damage.
Clogged vents.
|
|