TM 10-6640-238-13
2-34
Table 2-14. Operator Preventive Maintenance Checks and Services (PMCS)
NOTE
If equipment must be kept in continuous operation, only do procedures that can be
performed without disturbing operation. Make the complete checks and services when
equipment can be shut down.
BE - Before
AF - After
MO - Monthly
DU- During
WE - Weekly
Interval
Item No.
B
E
D
U
A
F
W
E
M
O
Item to Inspect
Procedures
Not Fully Mission
Capable If:
1
Exterior
Walls
Inspect skin surface. Refer to
TM 9-2330-362-14&P.
Wall skin cracked, or punctured.
Corrosion on hinges.
Storage Boxes
Inspect access doors.
Boxes or hardware missing.
2
a. Inspect for damage. Inspect
access door for defective or
missing latches, keepers,
seal, ball studs, and hinge.
Inspect water inlet
connection for damaged
threads and condition of
gasket.
Defective coupling or defective
gasket.
b. Inspect inlet connection plug. Defective or missing plug or
caps.
c. Inspect hose and adapters for
deterioration or damage to
threads.
Defective or missing hose
adapters. Damaged threads,
deteriorated/damaged hose.
Water Supply
Box
d. Inspect direction valve lever
for damage.
Damaged handle or missing
screws.
3
a. Inspect for damage.
Panel damaged or missing hinge.
b. Inspect power cable
connector.
Defective connector. Loose,
missing or damaged pins.
Power Panel
c. Inspect ground cable for
proper connection to ground
lug and grounding rod.
Grounding connections are
damaged. Safety clip missing.
4
Power Cables
Inspect cable for damage.
Cable connector or cable has
cuts and deep abrasions.
|
|