TM 10-6640-238-13
2-1
CHAPTER 2
OPERATING INSTRUCTIONS
Section I. DESCRIPTION AND USE OF CONTROLS AND INDICATORS
Alphabetical Index
Paragraph Title
Paragraph
Operator Controls and Indicators...................................................................................................................... 2-1
2-1.
OPERATOR CONTROLS AND INDICATORS.
All operators should become thoroughly familiar with the operators controls and indicators and with the proper operating
procedures for Modular Base Petroleum Laboratory (MBPL). Certain precautions must be observed in the operation of
equipment and its components. Exterior controls and indicators are shown in Figure 2-1 and described in Table 2-1. Circuit
breaker locations are shown in Figures 2-2 and 2-3 and described in Tables 2-2 and 2-3. Interior operators controls and
indicators are shown in Figures 2-4 through 2-13 and are described in Tables 2-4 through 2-13. Operators controls and
indicators for items not listed in these tables are described in their respective TMs (See Appendix A for TM number).
a.
Exterior Controls and Indicators. Figure 2-1 and Table 2-1 list exterior controls and indicators.
Table 2-1. Exterior Controls and Indicators
Index
Number
Control or Indicator
Function
Water Inlet
1
Water Inlet Adapter
Connection mates to a MS27020-10 male connector.
2
Garden Hose Adapter
Two adapters provided to connect a standard garden hose to the MBPL. One
with male and one with female connector.
3
Water Inlet/Outlet
Valve Selection Lever
Selects position of water inlet/outlet valve. Either IN or OUT for water
directional flow.
Power Panel
4
Purge Alarm Buzzer
Indicates by sound if one of purge doors is not opened when purge cycle is
initiated.
5
Power Input
Connector/ Receptacle
Input power connector for MBPL.
6
Outlet, 120V, 60 Hz
Receptacle for supplying generator power.
7
Ground Lug
Attach point for ground cable to ground MBPL.
8
Telephone Connection
External convenience outlet.
|
|