TM 10-6640-238-13
5-44
5-21. GUM BATH VENT/FUME VENT BLOWER AND MOTOR.
This task consists of:
a. Remove
b. Install
INITIAL SET-UP
Tools Required
General Mechanics Tool Kit, (Appendix B, Section III, Item 1)
Portable Electric Drill, (Appendix B, Section III, Item 2)
Twist Drill Set, (Appendix B, Section III, Item 2)
Hand Blind Riveter, (Appendix B, Section III, Item 3)
Materials/Parts Required
Lockwashers, (4)
Rivets (6)
General Safety Instructions
WARNING
ELECTRICAL SHOCK
Before performing any maintenance actions on electrical equipment, ensure all
electrical power has been turned off. Failure to comply with this warning may
result in serious injury or death.
REMOVE
Remove Gum Bath Vent/Fume Vent Blower and Motor. See Figure 5-17.
a.
At Power Panel No. 2, set circuit breaker A15CB11 OFF.
b.
Remove access panel from blower motor junction box (1). Tag and disconnect wiring and conduit (2).
c.
Loosen clamp (3) and disconnect discharge duct (4) from blower housing (5).
d.
Remove four nuts (6), eight washers (7), four dampers (8), and screws (9) securing motor bracket (10) to equipment
shelf (11).
e.
Loosen clamp (12) on suction duct (13) and remove blower motor (14) and motor bracket (10) from equipment shelf
(11).
f.
Remove four screws (15), eight washers (16), four lockwashers (17), nuts (18), and blower motor (14) from motor
bracket (10). Discard lockwashers.
g.
Remove three rivets (19) and reducer (20) from blower housing (5).
INSTALL
Install Gum Bath Vent/Fume Vent Blower and Motor. See Figure 5-17.
a.
Install reducer (20) and secure with three rivets (19).
b.
Position blower motor (14) on motor bracket (10) and secure with four screws (15), eight washers (16), four
lockwashers (17), and nuts (18).
c.
Place blower motor (14) and motor bracket (10) on equipment shelf (11) and secure suction duct (13) to blower
housing (5) by tightening clamp (12).
|
|