TM 10-6640-238-13
4-126
4-52. JET FUEL THERMAL OXIDATION TESTER (JFTOT).
This task consists of:
a.
Remove
b.
Install
c:
Calibrate
INITIAL SET-UP
Tools Required
General Mechanics Tool Kit, (Appendix B, Section III, Item 1)
Personnel Required
Two (2)
General Safety Instructions
WARNING
ELECTRICAL SHOCK
Before performing any maintenance actions on electrical equipment, ensure all
electrical power has been turned off. Failure to comply with this warning may
result in serious injury or death.
PHYSICAL LIFTING
Serious injury could occur if heavy equipment is moved/lifted without sufficient
personnel to do the job. Use proper physical lifting procedures or use a suitable
lifting device or dolly. Wear safety shoes, gloves and other suitable protective
clothing.
REMOVE
Remove JFTOT. See Figure 4-48.
a.
Unplug JFTOT power cord from wall receptacle.
b.
Unlatch three retaining latches (1) on both sides of JFTOT (2) from mounting frame (3).
c.
Slide unit out approximately two inches.
d.
Remove 12 cap nuts (4), nuts (5), and washers (6) that secure JFTOT foundation to countertop (7).
WARNING
Two people are required to remove JFTOT tester because of its weight. Failure to
comply with this warning could result in serious injury to personnel or damage to
equipment.
e.
Remove JFTOT (2) with mounting frame (3) from countertop (7).
f.
Remove JFTOT (2) from mounting frame (3).
|
|