TM 10-6640-238-13
4-8
Table 4-1. Unit Preventive Maintenance Checks and Services (PMCS) CONT
Q - Quarterly S - Semi-Annually A - Annually B-Bi-Annually
Item No.
Interval
Item to Inspect
Procedures
Not Fully Mission Capable If:
Q
S
A
B
10
Vacuum System
a. Check vacuum pump for good
condition and proper operation.
Refer to TM 10-4310-391-
13&P for further PMCS
instructions.
Vacuum pump inoperative, has
missing or loose mounting
hardware or fasteners, or loose or
broken electrical connections
b. Check system tubing and
piping for good condition.
System tubing and piping has
leaks.
c. Check system valves for good
condition.
System valves have leaks.
11
Water System
a. Check water pump for good
condition. Refer to TM 10-
4320-321-13&P for further
PMCS instructions.
Water pump has missing or loose
mounting hardware or fasteners, or
loose or broken electrical
connections.
b. Check water tank for good
condition.
Water leaks from tank or fittings,
or has missing or loose tank
mounting hardware or fasteners
c. Check surge tank for good
condition.
Water leaks from tank or fittings,
or has missing or loose tank
mounting hardware or fasteners
d. Check water pressure switch
and gauge for good condition.
Water pressure switch has loose
electrical connections or gauge is
broken or inoperative.
e. Check water filter for good
condition.
Water filter has leaks, or missing
mounting screws
f. Check water chiller for good
condition. Refer to commercial
manual for further instructions.
Water chiller inoperative or has
leaks. Water chiller has missing or
loose mounting hardware or
fasteners, or loose or broken
electrical connections.
g. Check water heater for good
condition and proper operation.
Water heater inoperative, water
leaks from heater, fittings, has
missing or loose mounting
hardware or fasteners, or loose or
broken electrical connections.
|
|