TM 10-6640-238-13
3-20
3-7.
ANEROID BAROMETER.
This task consists of:
a.
Remove
b.
Install
INITIAL SET-UP
Tools Required
General Mechanics Tool Kit, (Appendix B, Section III, Item 1)
Materials/Parts Required
Lockwashers, (3)
REMOVE
Remove Aneroid Barometer. See Figure 3-4.
a.
Remove three screws (1), lockwashers (2) and carefully remove aneroid barometer (3) from wall. Discard
lockwashers.
b.
Loosen two retaining ring clamp screws (4).
c.
Remove retaining ring (5) from barometer (3) and mounting cushion (6).
d.
Remove barometer (3) from mounting cushion (6). Retain cushion for installation.
INSTALL
Install Aneroid Barometer. See Figure 3-4.
a.
Install mounting cushion (6) on aneroid barometer (3) and insert into retaining ring (5).
b.
Tighten two retaining ring clamp screws (4) until aneroid barometer (3) is held securely in place.
c.
Install aneroid barometer (3) in place on wall and secure with three screws (1) and lockwashers (2).
|
|