TM 10-6640-233-10
b. Potable Source, Unpressurized System.
(1) Perform all steps above for Potable Source, Pressurized System (Paragraph 2-9a).
(2) Hook up the hose adapter, with garden hose, to the suction inlet (Figure 2-10) on the curbside exterior of
the van.
(3) Close the tank/pump valve (Figure 2-13).
(4) Open the Pump/Suction Valve.
(5) Turn on the water pump switch located in the main power panel (Figure 2-5) and proceed to fill the tank.
(6) Close pump/suction valve (Figure 2-13).
c. Unknown Water Source, Pressurized System.
(1) Hook up the garden hose as outlined in paragraph 2-9a above; however, switch the "WATER FLOW
FACILITY SUPPLY" to "FILTER" and switch the "FILTER VALVE" from "off" to "FILTER No. 1" (Figure 2-12).
(2) Proceed to fill the water tank as described in paragraph 2-9a.
NOTE
When "FILTER VALVE" filter No. I is dirty or needs servicing, you can switch to "FILTER No. 2"
position on the "FILTER VALVE" switch. These filters remove sediment from the water source.
(3) Set the "TANK/SYSTEM" Switch and the "WATER FLOW FACILITY SUPPLY" Switch to "SYSTEM".
(4) Set the "FILTER VALVE" Switch to "OFF".
(5) Close the pump suction valve (Figure 2-13).
(6) Open the Tank/Pump valve.
(7) Turn on the water pump switch located in the main power panel (Figure 2-5) to pressurize the system.
d. Unknown Water Source, Unpressurized System.
(1) Perform all steps in paragraph c above for Unknown Water Source, Pressurized System.
(2) Perform steps (2) through (6) in paragraph b above for Potable Source, Unpressurized System.
NOTE
The AOAP Mobile Laboratory is now operational and ready to process oil/grease samples from
aeronautical or Nonaeronautical components.
2-42
|
|