TM 10-4930-251-12&P
Salt mater corrodes metal. If unpainted equipment parts are exposed to salt hater.
clean them off irnmediatel~~
\\ itli an approved solvent and dry thoroughly.
All surfaces SI~OLIICI be cleaned daily.
b. Wipe clown the dispensin,(1 unit \vitli a liglitlv oiled rag to prevent corrosion
2-18. Operation at High Altitudes.
The procedures for operating the Low Profile Tank
Dispensing Unit are the same as under iisunl conditions except for the following special
precautions.
2-19. Emergency Procedures.
In a situation where clean filtered fuel is needed but the correct
hose coupling to connect to the bottom loadin g valve port is not available. it will be necessary to
till the tank through the manhole. Perform the follo\ving procedures to refuel tank through
maniiole fill opening.
a.
Refer to paragraph 2-9 and perform grounding procedures.
b.
Attach nozzle grounding clamp (10. Figure 2-l I ) to fuel tank being serviced.
c. Open manhole latch (9, Figure 2-l I) and till cap (8. Figure 2-1 1)
d.
Insert file1 supply nozzle (6, Figure 2-I I) into till tube (7, Figure
2- 1 I) of tank and fill tank.
e.
When tank is full. withdraw fuel nozzle. close fill cap and latch then disconnect nozzle
grounding clamp.
f.
Discomect static grounding rod, and return it to its stowed position.
FILL TUBE
NOZZLE
GROUNDING
CLAMP
Figure 2-l I
Emergency Retilling of Tank
2-14
|
|