Thl 10-4930-251-12&P
l-9. Equipment Data.
3lanufacturers
I
Tank
Heta S\~stems
ModeiiPart Number
I i176F2 I16
Capacity,
500 gal.
1 mgll
56 in.
Uidth
71 in.
Height
-3 0 in
Weight
500 Ibs.
f.i1pt>
7
-.
-Irailer D & S Manufacturing Co.
Model/Part
Number
Cubic Volume
Length
Width
Height
Weight
ICllOhlAI
458 cu. Ft.
232.62 in.
69 in.
37 in.
5,5 10 Ibs. Empty
15.850 Ibs. Gross
3
.
Holddown Assembl\
Model/Part
Number
13226E2
146
l-10.
Safety, Care and Handling. Observe all WARNINGS. CAUTIONS, and NOTES in this manual.
This equipment can be hazardous if these instructions are not follo\ved.
Section
III.
TECHNICAL
PRINCIPLES
OF
OPERATION
l-l 1.
Storage of Fuel.
a .
The 500-gal ion I iquid dispensin,~1 tank can be filled \\ith fuel after storage or servicing. It is
recommended that the tank not be used to store fuel for more than ten ( 10) calendar days beyond the
accomplished mission.
1-12. Dispensing of Fuel.
NOTE
The hand pump is a not issued item with this equipment.
a .
Using a hand pump coupled to the hand pump port on the top of the tank can also dispense fuel.
b.
Fuel is dispensed from the tank unit usin, b
u crravity flow procedures by connecting a dry disconnect
coupling and hose and nozzle assembly
to the bottom loading port at the fuel manifold. When the nozzle
handle is activated. gravity takes ober. allowing fuel then to flow through hose and nozzle to be dispensed
into vehicles needing refueling.
c. When it is necessary
to drain the contents of the tank, open the valve on the bottom of the tank
l-5/(1-6 blank)
|
|