Custom Search
 
  
 


TM 9-2330-330-14&P
ELECTRICAL WIRING REPAIR--Continued
0065 00
b.
Male cable connector:
1) Strip cable insulation equal to depth of terminal well.
2) Slide shell over cable.
3) Insert cable into terminal well.
4) Place "C" washer over cable at crimped junction and slide shell over "C" washer and
terminal.
c.
Female cable connector (with sleeve):
1) Strip cable insulation equal to depth of terminal well.
2) Slide shell and sleeve over cable.
3) Insert cable into terminal well and crimp.
4) Slide shell and sleeve over terminal.
0065 00-2



 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business