Custom Search
 
  
 


TM 9-2330-329-14&P
ELECTRICAL WIRING REPAIR
THIS WP COVERS:
Repair
INITIAL SETUP:
Maintenance Level
Tools and Special Tools
Organizational
Tool kit, general mechanic's (item 4, WP 0156 00)
Materials/Parts
Solder (AR) (item 14, WP 0159 00)
Tape, electrical (AR) (item 16, WP 0159 00)
ID bands (AR) (item 55, WP 0160 00)
REPAIR
1.
Check cable assemblies and leads for damaged insulation. Repair using electrical tape. If
insulation is too badly damaged to repair with tape, go to step 3.
2.
Check ends of wires for bent, broken, or damaged electrical connectors. Replace missing or
damaged connectors per step 5.
3.
Remove damaged wires from components. Cut off and discard electrical connectors.
4.
Measure length of removed wire and install new length of identical wire. After installing new wire,
replace electrical connectors per step 5 and tag wires with ID bands as necessary.
5.
Install new connector parts as follows.
a.
Terminal type cable connector:
1) Strip cable insulation equal to depth of terminal well.
2) Slide insulator over cable.
3) Insert cable into terminal well and crimp terminal.
4) Slide insulator over crimped end of terminal.
0062 00-1



 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business