Custom Search
 
  
 


TM 9-2320-279-10-3
Troubleshooting Index (Cont)
Table 3-5.
Troubleshooting
Malfunction
Test or Inspection
Corrective Action
1. 120 VAC RECEPTACLES DO NOT OPERATE.
Step 1. Check if any other 120 VAC circuits operate.
If all 120 VAC circuits do not operate, troubleshoot
hydraulic generator, no output voltage (malfunction 12).
408
CIRCUIT
BREAKER 16
CIRCUIT
CIRCUIT
CIRCUIT BREAKER
BREAKER 8
BREAKER 10
2 AND 4
NOTE
Circuit breaker may be in ON position when tripped. To make
sure circuit breaker is not tripped, reset circuit breaker by
switching it to the OFF position then back to ON position.
Step 2. If cord reel receptacles do not operate: Check if circuit breaker
2 or 4 is tripped.
If circuit breaker 2 or 4 is tripped, reset tripped circuit
breakers. If circuit breaker trips again, notify
Supervisor.
Step 3. If driver side pump house receptacles do not operate: Check if
circuit breaker 7 is tripped.
If circuit breaker 7 is tripped, reset circuit breaker. If
circuit breaker trips again, notify Supervisor.
Step 4. If passenger side pump house receptacles do not operate:
Check if circuit breaker 8 is tripped.
If circuit breaker 8 is tripped, reset circuit breaker. If
circuit breaker trips again, notify Supervisor.



 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business