TM 10-6640-233-10 Table 31.  Troubleshooting (cont.) MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 1.  NO ELECTRICAL POWER TO LABORATORY (PURGE SYSTEM DOES NOT OPERATE). (cont.) Step 4.  Check that main power cable is properly connected to laboratory electrical power receptacle. WARNING Do not attempt to disconnect or connect main power cable to laboratory electrical receptacle with generator set applying power to the cable.  Death or serious injury may result. a.  Place-generator output power switch OFF. b.  Make proper power cable connection. c.  If purge system still fails to operate, notify unit maintenance. WARNING If purge cycle has not taken place, do not enter the laboratory without first allowing the laboratory to  vent  to  the  atmosphere  via  the  two  laboratory  doors  for  a  minimum  of  20  minutes.    Death  or serious injury could result. 2.  CEILING LIGHTS FAIL TO COME ON. Check and reset Main Power Panel circuit breaker No.  13. If lights still fail to operate, notify unit maintenance. 3.  WHITE CEILING LIGHTS FAIL TO COME ON (BLACKOUT LIGHTS ARE ON). Check operation of the door interlock switches. a.  Ensure door interlock switches are closed.  White lights should come on. b.  If white lights do not come on, notify unit maintenance. 4.    WHEN  ONE  OF  THE  AOAP  MOBILE  LABORATORY  DOORS  IS  OPENED,  WHITE  LIGHTS  FAIL  TO  GO  OFF AND BLACKOUT LIGHTS FAIL TO COME ON. Check operation of the door interlock switch. a.  Adjust door interlock switch. b.  If lights still fail to operate properly, notify unit maintenance. 3-2


 